Herunterladen Diese Seite drucken

Troubleshooting - Lincoln industrial HP-500W Benutzerinformation

Handpumpen für fett

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Benutzerinformation / Owner Manual
Handpumpen für Fett Typ HP-500W und Typ HP-500W-SSV
Hand Pumps for Grease, Models HP-500W and HP-500W-SSV

Troubleshooting

Fault: Pump does not deliver
Cause:
Air pockets in the grease
Suction hole is clogged by foreign particles
Fault: Hand lever blocked (no delivery possible
Cause:
Lubrication point clogged. Progressive metering device
blocked
Note: According to the progressive system principle, the entire system will be blocked if one of the lubrication points is
clogged. This feature is at the same time a means of monitoring the entire progressive system.
Further information: Refer to Technical Description SSV
Model HP-500W
Änderungen vorbehalten
LINCOLN GmbH ∗ Postfach 1263 ∗ D-69183 Walldorf ∗ Tel +49 (6227) 33-0 ∗ Fax +49 (6227) 33-259 ∗Tx 466088
Remedy:
pump must be vented:
Unscrew the grease reservoir by approx. 2 turns
Press vigorously and several times against the piston
rod until the entrapped air is removed and grease
emerges at the female thread of the reservoir. If air
pockets cannot be eliminated in this ay, remove the
grease from the reservoir and repeat filling.
Unscrew and remove grease reservoir and clean the
suction hole
Remedy:
Loosen all lubrication point connections on the SSV
metering device one after the other in order to find the
blocked lubrication point
Eliminate the blockage
Model
HP -500W-SSV6
HP -500W-SSV8
HP -500W-SSV10
HP -500W-SSV12
Subject to change
2.1B-28005-A97
Dim 'A'
(mm)
60
75
90
105
Seite /page 7 von/of 7

Werbung

loading

Diese Anleitung auch für:

Hp-500w-ssv