OPERATING PRESSURE ADJUSTMENT
The pressure switch is located on the top of the sprayer. Sprayer operation at 1.3 bar (Fig. 10a). Sprayer
operation at 3 bar (Fig. 10b).
Fig.10a

STORAGE AND MAINTENANCE

After each use, rinse the sprayer system thoroughly with clean water. Dilute the remaining spraying liquid in the
tank with water (approx. 2 litres) and then rinse the sprayer system by activating pumping until the tank is empty.
It is best to repeat the washing process up to 3 times. Rinse the strainer too.
The filter (Fig. 1 1/item 1) located in the lance handle (Fig. 1 1/item 3) and the nozzle (Fig. 12/item 1) at the end
of the lance (Fig. 1/item 7) should be cleaned periodically or before any extended period without operation.
PL
EN
DE
RU
Fig.1 1
1
The same applies to the filter at the bottom of the main tank (Fig. 14/item 2). The filter can be accessed by
unscrewing the filling unit safety cap (Fig. 1/item 3). The filter is located at the bottom of the tank.
Replacement of the nozzle in the lance.
Unscrew the lance tip nut (fig. 12 / item 2). Replace the nozzle (fig. 12 / item 1). Screw the lance tip nut with
the nozzle onto the lance until it is airtight.
Nozzle replacement can be done without removing pressure from the device.
The sprayer should be stored WITHOUT PRESSURE IN THE PRESSURE TANK at +5°C to +35°C in shaded
and dry places, away from heaters and out of reach of children. The device may be transported holding it by the
straps (Fig. 1/item 2) or by the transport handle on top of the device (Fig. 1/item 6).
De-pressurising the pressure tank:
1. Point the tip of the lance at the previously sprayed surface.
2. Press the lever (Fig. 1 1/item 2) and start spraying.
3. Continue spraying until no spraying liquid or pressure is emitted from the lance tip.