6.2 | Error messages

:
The battery is incorrectly connected to the charger (reversed polarity).
:
The battery is faulty.
+
: A battery clamp is not attached or is incorrectly attached.

7 | Features

• Charging current selection: 1 A or 4 A max.
• Automatic charging voltage adjustment with multi-stage charging characteristic
(I-phase, U-phase)
• Suitable for 6 V (3 cells) and 12 V (6 cells) lead-acid, lead-gel, lead-fleece, AGM,
calcium and pure-lead vehicle batteries
• Special charging mode for AGM batteries
• Battery test function
• Desulphation function* for sulphated batteries
• Regeneration function* for deeply discharged batteries
• Trickle charging function and overcharge protection
• Reverse polarity protected, short-circuit-proof and spark-proof. Internal
temperature monitoring
• Operating voltage: 220-240 V/AC (50/60 Hz)
• Ambient temperature: -15°C to +45°C
The battery charger is designed for an operating temperature of -15°C
to +45°C. Refer to the battery manufacturer's instructions for the
permissible temperature range for charging.

8 | Functional description

8.1 | Explanation of steps 1 – 7
Step 1 "Analysis": An analysis is performed to determine whether a battery is
connected and the battery voltage is within the valid range.
Step 2 "Check": The connected battery is checked for deep discharge and
sulphation.
Step 3 "Recovery": Depending on the state of the battery, it is pre-charged,
if necessary. During the recovery process, the battery is fed with a pulsating
current. This process can take up to one hour.