7. Set-up of the Crimping Machine

1. Place the machine at the final work location. The adjustable feet are used to place the machine firmly onto
the work surface and secured in place with the lock nuts. A secure setup of the machine is of upmost
importance.
2. Connect the supply hose for the compressed air. The built-in pressure gauge is set at the factory and
limits the air pressure to a max. of 6 bar. Please ensure the proper connection of air supply hose. In order
to operate the machine safely, the air pressure needs to be between 5-6 bars.
3. After connecting the supply lines, the machine needs to be inspected for leaks and for the correct ope-
rating pressure.
Square Counter Bearing
Shut-off Valve
Plug Nipple for Quick-connect
Pressure Gauge
Pressure Display/ Manometer
Lock Nuts