Safety Notes

Gloves should be worn during installation to prevent
crushing and cutting injuries.
The shower system may only be used for bathing,
hygienic and body cleaning purposes.
The hot and cold supplies must be of equal pressures.

Installation Instructions

• Prior to installation, inspect the product for transport dam-
ages. After it has been installed, no transport or surface
damage will be honoured.
• The pipes and the fixture must be installed, flushed and
tested as per the applicable standards.
• The plumbing codes applicable in the respective coun-
tries must be oberserved.
• Important! There must be an access door for mainten-
ace.

Technical Data

Operating pressure:
Recommended operating pressure:
Test pressure:
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
Recommended hot water temp.:
Thermal disinfection:
• Safety against backflow
• The product is exclusively designed for drinking water!
Fault
Insufficient water
Mixer stiff
Mixer dripping
Hot water temperature too low
Instantaneous heater didn't work
4
English
max. 1 MPa
0,1 - 0,5 MPa
1,6 MPa
max. 80°C
65°C
max. 70°C / 4 min
Cause
-check valve hasn't moved back
-Shower filter seal dirty
-Cartridge defective, calcified
-Cartridge defective
-Hot water limiter incorrectly set
-Flow limiter in handshower isn't re-
moved
-Shower filter seal dirty
-check valve hasn't moved back
Assembly see page 31

Symbol description

Do not use silicone containing acetic acid!
Adjustment (see page 33)
To adjust the hot water limiter. Using a hot
water limiter in combination with a continuous
flow water heater is not recommended.
Operation (see page 34)
Dimensions (see page 35)

Flow diagram

(see page 35)
Tub outlet
Shower outlet 1B resistance
25 l/min (0,3 MPa)
Maintenance (see page 36)
The check valves must be checked regularly
according to DIN EN 1717 in accordance
with national or regional regulations (at least
once a year).
Spare parts (see page 37)
Cleaning (see enclosed brochure)
Remedy
-Exchange check valves
-Clean filter seal between shower and
hose
-Exchange cartridge
-Exchange cartridge
-Set hot water limiter
-Remove flow limiter
-Clean filter seal between shower and
hose
-Exchange check valves

Werbung