Additional possible errors of inverter with integrated charger
Symptom
charger does not work
charger only supplies low
current
charging does not function
despite shore power
connection
Caution!
Immediately eliminate error sources!
Make sure that error sources are eliminated . Multiple restarts due to unsolved errors
can destroy the inverter .
Especially prevent short circuits and polarity reversals because they can destroy the
device despite protection .
62
[
ECTIVE
SINUS/SINE INVERTER – CSI-/SSI-SERIES
®
Possible reason
parameters of input
voltage are outside of
tolerance
low input voltage
one or several batteries
are not connected / defect
1 . one or several batteries
defect
2 . battery fuse defect
3 . battery cable defect or
damaged
4 . charger defect
Solution
check voltage and frequen-
cy of input source
use the right AC voltage
check all connections
1 . check battery,
change if necessary
2 . check fuse,
change if necessary
3 . check cable,
change if necessary
4 . contact producer/dealer
]

Werbung