Operating performance MPPT-charge controller
(SSI100 to 300-series)
Battery voltage
Charge efficiency
Solar input voltage
Max . input current
Max . input power
Recommended surrounding conditions
Operating temperature
Storage temperature
Relative humidity
☝
Please note!
Please mind the starting current!
Keep in mind that inductive devices (for example power drills or refrigerators etc .) often
need a 3–10 times higher power at the beginning than indicated on the descriptive
type plate . The maximum power of this short period should not surpass the maximum
power of the inverter .
☝
Please note!
Listen to the acoustic signal!
In case of overload an acoustic signal will sound . If the needed power is not reduced to
the maximal continuous output, the inverter will shut down automatically .
☝
Please note!
Output losses because of heat
An ambient temperature over 40°C (for ex . due to heat at the installation site or direct
sunlight) can lower the specified output and efficiency .
48
[
ECTIVE
SINUS/SINE INVERTER – CSI-/SSI-SERIES
®
12 V
15 – 70 V
20 A
-15 °C bis 40 °C
-40 °C bis 85 °C
20 % ~ 90 %
24 V
48 V
> 97 %
24 – 70 V
48 – 70 V
10 A
5 A
550 W
]