GENERAL DESCRIPTION
ALARM MANAGEMENT
If this function is activated, the actuator completely opens or closes the roller shutters (Venetian blind,
motorised curtain) for safety reasons when a message is received from a wind or rain sensor.
The selection if they should be opened or closed is set during programming.
As an additional safety measure, if the actuator does not receive a no alarm message from the sensor
for more than 30 minutes, it interprets this as a fault and, as a result, brings the roller shutter to the pre-
defined safety position. The alarm status will last as long as the actuator does not receive a no alarm
status.
At the end of the alarm, the actuator returns the roller shutter to its initial position (or carries out the last
command received, if it received commands during the alarm phase).
EXECUTION OF PRIORITY COMMANDS
When receiving a command that orders forcing, it brings the roller shutter to the set position (UP or
DOWN). As long as the priority command is not revoked, the actuator will ignore all other commands
it receives, including rain and wind alarms.
When the priority command is revoked, the actuator returns the roller shutter to its initial position
(or carries out the last command received, if it received commands during the priority command).
SCENE MANAGEMENT
The actuator is able to store and execute up to 8 scenes, and a precise position (UP, DOWN and
intermediate) can be associated to each of them.
The scene can only be learned when the roller shutter is stopped.
Position the roller shutter in the desired position before storing the scene.