Herunterladen Inhalt Inhalt Diese Seite drucken

Gewiss Chorus GW 10 755 Handbuch Seite 23

6-kanal-sendeeinrichtung mit schaltgeber für die motorsteuerung easy
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 67
The motor actuator is able to manage the movement, alarm and priority commands at the
same time. If multiple modes are active at the same moment, the actuator will execute the
one with the highest priority. The priority of the various functions, from the maximum to the
minimum, is as follows:
• The actuator behaviour when the BUS voltage fails
• Priority commands
• Alarm management
• The actuator behaviour when the BUS voltage returns
• Roller shutter/Venetian blind movement, scene management,
local control push-buttons
ROLLER SHUTTER MOVEMENT
Raises or lowers the roller shutters, or stops their movement, when the relative command is received.
If the stop command is not sent, the motor is stopped only at the end of the Movement time: therefore
the roller shutters should be equipped with a stop sensor or an automatic clutch.
VENETIAN BLIND MOVEMENT
ATTENTION: in order to make complete use of this mode, it must be possible to
mechanically adjust the slats of the Venetian blinds with small up/down
movements of the motor.
The Venetian blinds may be raised or lowered, or their movement may be stopped by sending the
relative command. The slats are rotated when, with the Venetian blinds stopped, the actuator receives
a brief movement command.
If the stop command is not sent, the motor is stopped only at the end of the Movement time: therefore
the Venetian blinds should be equipped with a stop sensor or an automatic clutch.
GENERAL DESCRIPTION
Functions - actuator section
23
MAX PRIORITY
MIN PRIORITY
E
N
G
L
I
S
H

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Chorus gw 12 755Chorus gw 14 755

Inhaltsverzeichnis