Herunterladen Inhalt Inhalt Diese Seite drucken

Electrical Connection; Dimensions Of Housing - Electrolux IG 0940 Benutzerinformation

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

INSTALLATION
Location
The appliance should be installed well away from
sources of heat such as radiators, boilers, direct
sunlight etc. See the enclosed built-in instructions.

Electrical connection

Before plugging in, ensure that the voltage and
frequency shown on the serial number plate
correspond to your domestic power supply. Voltage
can vary by ±6% of the rated voltage.
For operation with different voltages, a suitably sized
auto-transformer must be used.
The appliance must be earthed.
The power supply cable plug is provided with a
contact for this purpose.
If the domestic power supply socket is not earthed,
connect the appliance to a separate conductor in
compliance with current regulations, consulting a
qualified technician.
The Manufacturer declines all responsibility if
the above safety precautions are not observed.

Dimensions of housing

Height
880 mm
Depth
550 mm
Width
560 mm
For safety reasons, minimum ventilation must be as
shown in Fig.
Attention: keep ventilation openings clear of
obstruction.
It is necessary that the niche is provided with a
ventilation conduct having the following dimensions:
Depth
50 mm
Width
540 mm
This appliance complies with the following
E.E.C. Directives:
-
87/308 EEC of 2/6/87 relative to radio
interference suppression.
-
73/23 EEC of 19.2.73 (Low Voltage Directive)
and subsequent modifications;
-
89/336 EEC of 3.5.89 (Electromagnetic
Compatibility Directive) and subsequent
modifications.
ATTENTION!
It must be possible to disconnect the appliance from
the mains power supply; the plug must therefore be
easily accessible after installation.
50 mm
D567
PR01
min.
2
200 cm
min.
200 cm
2
B
T H
33