Herunterladen Inhalt Inhalt Diese Seite drucken

Troubleshooting Guide - EINHELL GC-DW 1000 N Originalbetriebsanleitung

Vorschau ausblenden Andere Handbücher für GC-DW 1000 N:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 4

10. Troubleshooting guide

Faults
The equipment
- Power supply not connected
does not start
The equipment
- Intake sieve clogged
does not pump
- Discharge hose kinked
Insuffi cient pumping
- Intake sieve clogged
rate
- Performance reduced due to heavi-
The equipment swit-
- Motor circuit-breaker switches the
ches off after briefl y
running
- Water temperature too high; motor
Anl_GC_DW_1000_N_SPK9.indb 16
Anl_GC_DW_1000_N_SPK9.indb 16
GB
Cause
ly contaminated and abrasive water
impurities
equipment off due to excessive wa-
ter contamination
circuit-breaker switches the equip-
ment off
- 16 -
Autogoods "130"
Remedy
- Check power supply
- Clean intake sieve with water jet
- Unkink the hose
- Clean intake sieve
- Clean equipment and replace wear
parts
- Unplug power plug and clean
equipment and shaft
- Ensure that maximum permissible
water temperature (35 °C) is not
exceeded
30.01.2019 08:12:03