AGP R13 Betriebsanleitung Seite 11

Ringsäg
Inhaltsverzeichnis
Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 19
WATER FEED VALVE
The water flow is controlled by the water feed valve. The water to the
blade may be finely adjusted to the required amount.
NOTE: Contaminants in the water supply can easily plug up the
fine water nozzles in the blade guard. Ensure that the supply
water is clean. If you find that there is no water flow to the
blade, then clean out the water feed system on the machine with
compressed air.
OVERLOAD PROTECTION, OVERHEAT PROTECTION
Overload & Load Warning Lamp
When full load is reached, the load warning lamp will flash red. If
full load is exceeded and sustained for too long, the motor will shut
down and the load warning lamp will glow solid red. In this case, the
motor must be first shut off and then restarted. When this happens,
the motor will very likely be near overheating, so it is also a good
idea to run the motor at no load for a few minutes to cool it before
continuing.
Overheat Thermal Protection
If the temperature of the motor gets too high, the thermal protection will shut the motor down. The switch
must be first shut off and then restarted. When this happens, do not immediately start cutting after restarting
the motor. Always run the machine at no load for a few minutes to return to a normal operating temperature
before continuing.
CAUTION: The motor will be damaged if it is repeatedly overloaded or overheated. Always cool the
motor by running at no load for a few minutes whenever it stops from either overheat or overload.
SET UP
Connect the water supply
Check for water leaks
Connect to the power supply
THE SWITCH:
To start the machine, first press the Release Button, then press the
Trigger Switch.
To stop the machine, release the Trigger Switch.
GB
Load Warning Lamp
11
Water Feed
Open
Valve
Closed
Trigger Switch
Release Button

Quicklinks ausblenden:

Inhaltsverzeichnis
loading

Inhaltsverzeichnis