Refer to figures 1 to 5 at the beginning of the manual.
1
I/O switch
2
EVERFLO motor pump
3
pressure regulation knob
4
pressure regulation valve
5
DIN4165 type battery charging socket
6
pressure gauge
7
module protection cover
8
battery retention bracket
9
reduction bracket for battery
CAUTION
• If one or more labels should become damaged during use, contact the Manufacturer or Specialist
Technician for replacement.
The identification label (18) displays the model of the CBM module, serial number, year of manufacture
and the main electrical and mechanical specifications (maximum pressure, weight, supply voltage,
consumption etc.).
a) Pressure switch.
This device, calibrated by the Manufacturer, allows the maximum operating pressure to be limited,
preventing dangerous pressures from occurring when shutting off the delivery line or when attempting
to set pressures above maximum permitted values.
CAUTION
• The pressure switch is calibrated by the motor pump Manufacturer. Do not recalibrate.
b) Motor pump protection fuse.
This device stops operation of the motor pump in the event of overcurrent.
In the event of intervention, proceed as follows, observing the instructions given in the manual of
the machine that incorporates the CBM module:
• stop the machine and disconnect the power supply;
• purge any residual pressure from the high pressure circuit;
• replace the fuse (also refer to the section
• reconnect the power supply and repeat the start-up procedure.
CAUTION
• In the event of repeated intervention, do not use the motor pump (and therefore the machine that
incorporates it) without first having it checked by a Specialist Technician.
24
COMPONENT IDENTIFICATION
CBM MODULE IDENTIFICATION LABEL
SAFETY DEVICES
"s
peCiFiCations anD teChniCal Data
10
battery (optional)
11
battery charger power cable
12
battery charger
13
battery charging cable with DIN 4165 plug
14
sprayer lance with nozzle
15
delivery hose
16
by-pass hose (optional)
17
suction hose
18
identification label
";