5.6 Extraneous Voltage (Error Code 1)

The IE-CT resists to extraneous voltages (short time up to 100 V). If extraneous voltages should appear
in the installation the IE-CT can show their polarity and the respective conductor. The positive pole of
an extraneous voltage is displayed by continuous lighting, and the negative pole is displayed by flashing
of the respective conductor LED (F).
If an extraneous voltage is detected in an installation the test run is finished. To test this line on
installation errors shut off the extraneous voltage and start a new test run.
The error code for extraneous voltage is digit 1.

5.7 Connection Error (Error Code 2)

If the conductors are not interconnected (short circuit) and the IE-CT Test Box is not linked the IE-CT
Mainframe displays a connection error. In this case either the IE-CT Test Box or the IE-CT Mainframe
are not plugged in at all or plugged into the wrong jack.
The error code for connection errors is digit 2.

5.8 Conductor Interrupt (Error Code 3)

In case of conductor interrupts at the tested installation or cable, the red conductor LED (F) of the
IE-CT displays all interrupted conductors. Select the number of conductors of the installation by using
the Selection Switches (C) before you start the test run.
The error code for conductor interrupt is digit 3.

5.9 Short Circuit (Error Code 4)

If the IE-CT detects a short circuit between two or more conductors, the conductor LED (F) will display
all interconnected conductors. If more than one short circuit is detected, they are displayed as individual
errors. Even if the IE-CT Test Box is not terminated the IE-CT Mainframe displays short circuits.
The error code for short circuit is digit 4.
Note
Terminating resistors used in an installation are also recognized as short circuits.
22