After the last error is displayed a flashing digit is
shown in the numeric display (B). This digit stands
for the number of the connected Test Box.
'
If you press the Step Key (H) again as long as the Test Box number is flashing, the error list is
shown a second time, see item
(
For repeated testing continue as described under item
The IE-CT Mainframe can be turned off at any time by pressing the Start Key.

5.4 Line Identification

The IE-CT Mainframe recognizes up to nine different IE-CT Test Boxes. This feature allows the user to
run installation tests and line identifications at nine different lines in one operation.
Turn on the IE-CT and press the Step Key (H). The numeric display shows the Test Box number as a
flashing digit (B). If a flashing bar appears instead, the IE-CT Mainframe did not recognize the number
of the IE-CT Test Box.

5.5 Selection of Contact Assignment

Not all installations use shielded 8 conductor cables. Therefore the IE-CT Mainframe offers the
possibility to separate unused contacts for the test. Contact assignment can be adjusted with the
Selection Switches (C).
Selection Switches 1 to 9
Adjust the nine Selection Switches after removing the protective cover. Switch 1 to 8 stand for
conductors 1 to 8, switch 9 stands for the shield of the termination.
Note
Make sure that at least one conductor with an even and one with an odd number are selected,
i. e. conductor 4 and conductor 5.
!
.
21
%
.
Switch set "ON" means the
corresponding wire has been
connected.