BES Q08ZC-YPL20B-BP00,3-GS_ _
Inductive Sensors
5

IO-Link Functions

5.1

Process data

5.1.1

Output data

The sensor transmits a byte of process data to the master.
Process data byte 0:
7
6
Teaching
unsuccessful
Bit
Parameter name
0
Switching Signal of SSC1
1
Target too close
2
Target outside of detection
range
3
Idle
4
Teach process active
5
Teach process ended
sucessfully
6
Teaching unsuccessful
7
Idle
5.1.2

Input data

The sensor does not receive any process data from the
master.
8
english
5
4
Teach
Teach
process
process
ended
active
sucessfully
Description
Switch point information from
Binary Data Channel 1
Collision risk sensor target
Unreliable range. Target
outside of detection range
Teach process active
Teach process ended
successfully
Teaching unsuccessful
3
2
Target outside
Target too
of detection
range
Value
1
Active
Target too close Teach-In
blocked
Target outside of detection
range Teach-In blocked
Teach command running
Teach command ended
successfully
Teaching unsuccessful
1
0
Switching
close
Signal of
SSC1
0
Inactive
Default
Default
Default
Default
Default
Default
Default