Data sheet and general instructions
Explanation of the type
designation
Connection voltage
Frequency
Type of current
Power
Norm. volumetric air flow
Pressure
Filter area
Filter insert
Max. volumetric air flow
Min. volumetric air flow
Fan
Control panel level of
protection
Duty cycle
Dimensions
Weight
Welding fumes extraction
class and separation
performance
Use for the intended
purpose
Excluded uses
Type of cleaning
Compressed air
Control system and warning
signals
Noise emission
Permissible ambient
conditions
Storage conditions
0000100519/121212/0 MDB-2X/2F/4F
Number of filter cartridges
V
Hz
Ph
kW
m
/h
3
Pa
m²
m³/h per filter cartridge
See the fan table
%
mm
Kg
Pressure and quality
Consumption
Monitoring of air volumes and
lifetime of the filter cartridges
Direction of rotation of the
drive
dB(A)
°C (°F)
Atmospheric humidity
MDB-4-w3
2-4
1600
3750
1600
550
40
4 x times 10 m² filter
cartridges Cart-PTFE
Ref. 6840-1011
1000
350
See illustration
W3
> 99%
Extraction of fumes that are
released in the course of using
welding equipment for cutting
and joining non-alloy and
alloy steels, including high-
alloy chromium/nickel steels
with a nickel and chromium
content of ≥ 30%
- Welding fumes containing oil
- Aluminium dust
- Burning or incandescent materials
- Cigarettes
- Aggressive media
- Water and moisture
- Explosive gases and/or dust mixtures
- Dusts with toxic characteristics other than welding fumes
Pulse jet
Minimum 4 bar and maximum 6 bar
Dry and oil-free
50 Ndm³ free air per pulse
- A pressure switch monitors the pressure drop across the filter
cartridges and activates a visual warning signal.
- A flashing lamp is to be fitted. This performs 65 +/- 10
flashes per minute at 700-1000 cd in accordance with ISO-EN
842+A1.
- Warning signal activation at loss of pressure 1500 Pa in the
course of 1 hour or longer acts as a request to exchange the
filter cartridge.
• Install the flashing lamp where it can easily be seen and
connect it in parallel with an alarm lamp on the control
panel SCP, Cont.B or Cont.C.
Display indicating direction of rotation on the motor
If the direction of rotation is incorrect, swap over two phases in
the motor connection box.
See the fan table
Min.
Norm.
Max.
Temperature in storage 5-45°C (41-104°F)
Atmospheric humidity in storage 75%
MDB-4-w2
400
50
3
2,2
1600
3750
1600
550
50
4 x times 15 m² filter
cartridges Cart D with min. 40
gram precoat per filter
cartridge Ref. 6815-1011
1500
525
IP 55
100
425
W2
> 98%
Extraction of fumes that are
released in the course of using
welding equipment for cutting
and joining non-alloy and alloy
steels, including high-alloy
chromium/nickel steels with a
nickel and chromium content of
≤ 30%
5 (41°F)
20 (68°F)
45 (104°F)
75%
EN - 4