• "PAr" Parameters Menu
Table 1
"PAr"
CO2hi
CO2lo
CO2st
CO2Sr
VLO
VHI
nLO
nHI
Pstd
Percentage of standard modulation of nominal speed
Pbst
PnGt
Pmed
Phol
Tbst
TCOOL
Cooling setpoint temperature for freeheating management
THEAT
Heating setpoint temperature for freecooling management
Summer season transition temperature for pre-cooling management
Test
Winter season transition temperature for antifreeze management
Tinv
SPrc
RHnSP
Number of samples to calculate dynamic humidity setpoint
Flife
Relative humidity for Minimum Humidity mode activation
HrLO
Hrst
HrHiF
HrHi
Relative humidity for Maximum Humidity mode activation*
FLUSH
ErHs
Func
FUNCTIONS blocking operation (see dedicated paragraph)
* Available only if the functions feature air quality sensors
90
DESCRIPTION
Maximum CO2 level *
Minimum CO2 level *
Nominal CO2 level *
Full-scale CO2 *
Minimum control voltage in calibration
Maximum control voltage
Minimum speed in operation
Maximum speed
Percentage of boost/party modulation
Percentage of night modulation
Percentage of intermediate modulation
Percentage of minimum - holiday modulation
Boost/Party Time
geothermal coil
geothermal coil
Percentage imbalance between flow rates
Filter service life
Relative humidity lower limit in the comfort range *
Relative humidity upper limit in the comfort range *
Shows the HrHi parameter
Summer Mode activation
Speed of Low humidity
This menu allows you to modify the operating pa-
rameters of the appliance. With the controller "ON",
press "M" and On/Off simultaneously for 3 seconds.
Select the "PAr"menu using the TOUCH PAD and
confirm by pressing "Enter". Select the parameter to
be modified by using the TOUCH PAD and confirm by
pressing Enter". Once the parameter is selected, the
value will be displayed. The value can be modified
using the TOUCH PAD. Press the"M" button once to
return to parameter selection; to exit the menu, press
the "M" button 3 times.
*
RANGE
DEFAULT
1500 ÷ 2000 ppm
400 ÷ 600 ppm
900 ÷1100 ppm
2000 ÷ 30000 ppm
-10% ÷ +10%
See table 2
-10% ÷ +10%
See table 2
-10% ÷ +10%
See table 2
-10% ÷ +10%
See table 2
100% ÷ 110%
110% ÷ 130%
45% ÷ 100%
35% ÷ 70%
0 ÷ 35%
60 ÷ 240 min
10 ÷ 30°C
10 ÷ 30°C
10 ÷ 30°C
10 ÷ 30°C
-20% ÷ +20%
1 ÷ 96
96 (15 min)
30 ÷ 400 days
180 days
20 ÷ 45
40 ÷ 50
On ÷ Off
60 ÷ 80
On ÷ Off
2 speed
1 ÷ 4 speeds
-
1500
500
1000
2000
100%
130%
70%
45%
25%
180
26
20
18
24
0%
25
45
Off
65
OFF
-