Connection with remote control
The control is provided by default fitted on the appli-
ance, however it can also be remoted by fitting it on
the wall.
Always disconnect power
before accessing the unit.
1- Remove the controller from the front panel using
the suction cup accessory.
2- Remove the 3-pole connector coupled to the controller.
1
1a
2
70
3) Unscrew the top cover to access the electric com-
partment where the power board is located.
3
4) Remove the cable connected to the "CONTROL"
connector (terminals 1-2-3) of the power board.
4
CONTROL
5) Perform the new connection to position the con-
troller on the wall, respecting the sequence of the
terminal numbers:
a) apply the supplied cable gland as indicated in the
figure;
b) fix the cable in the cable gland;
c) connect the cable to terminals1-2-3 from the power
board to the controller respecting the numbers;
1 2 3
PG7
CONTROL