Herunterladen Diese Seite drucken

Siemens SIMATIC TP700 Comfort INOX Produktinformation Seite 2

Customized automation comfort panels inox, itc inox

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

SIMATIC
Customized Automation
Comfort Panels INOX, ITC INOX
Product Information
Applicability
Together with the compact operating instructions "Comfort Panels INOX, ITC INOX",
this document is valid for the following devices:
● TP700 Comfort INOX,
article number 6AV2144-8GC10-0AA0
● TP700 Comfort INOX PCT, article number 6AV2144-8GC20-0AA0
● TP900 Comfort INOX,
article number 6AV2144-8JC10-0AA0
● TP900 Comfort INOX PCT, article number 6AV2144-8JC20-0AA0
● TP1200 Comfort INOX,
article number 6AV2144-8MC10-0AA0
● TP1200 Comfort INOX PCT, article number 6AV2144-8MC20-0AA0
● TP1500 Comfort INOX,
article number 6AV2144-8QC10-0AA#
● TP1900 Comfort INOX,
article number 6AV2144-8UC10-0AA#
● ITC1900 INOX,
article number 6AV6646-8AC10-0AA0
# = 0: Based on the Comfort V1 device; # = 1: Based on the Comfort V2 device.
Safety information, as well as the complete installation and commissioning, are described here:
https://support.industry.siemens.com/cs/ww/en/ps/24409/man
Note
This document belongs to the device and will also be required for repeat commissioning. Keep all
supplied and supplementary documentation for the entire service life of the device.
Pass on all of these documents to a future owner of the device.
Mounting instructions
● Remove all packaging components and the edge protection tape prior to installation.
The technical specifications given for the device are guaranteed if these conditions are fulfilled:
● The device is installed by qualified personnel.
● The installation is performed as specified in this document.
Inserting the mounting seal
The following figures in this section are examples.
To prevent the mounting seal from being inserted in the wrong position, it has an asymmetric
coding tap. On all mounting seal of the INOX devices, the coding tap is on the bottom left in rela-
tion to the rear of the device.
Note
Use a new mounting seal for each installation, because the promised degree of protection cannot
be guaranteed otherwise.
Procedure
1. Look for the coding tap on the mounting seal. Turn the mounting seal so that the coding tap is
on the bottom left as seen in the figure below:
Coding tap
Positioning hooks
Seal corner
2. Carefully place the device on the front of the device (interfaces point to you).
3. Insert the mounting seal into the stainless steel front as shown. Also note points
Seal corner is underneath the housing frame.
The positioning hook of the seal fully engages into the cut-out, flat without protrusion.
The coding key lies flat in the intended cut-out.
4. Check the correct fit of the mounting seal:
– The coding tap is placed at the specified location.
– All positioning hooks rest flush in their cutouts. The mounting seal is installed correctly
when it lies flat on the entire stainless steel front. This must not lead to distortions and
protrusions.
If necessary, correct the seat: To do this, press the mounting seal into the recess.
– The edge of the mounting seal is flush with the edge of the stainless steel front all around.
© Siemens AG 2019. All rights reserved
A5E33472157-AH, 03/2019
A5E33472157
Mounting the device
The following process describes installation for all devices based on the example of the
TP700 Comfort INOX.
Requirement
● 1 clamping frame
● 1 Allen key 2.5 mm
● Mounting clips: depending on the display size generally:
7" devices: 10 mounting clips
9" devices: 13 mounting clips
12" devices: 12 mounting clips
15" devices: 20 mounting clips
19" devices: 18 mounting clips
Observe the additional product information, if any, supplied with the product.
Installation
CAUTION
Risk of injury when device falls
An unsecured device may fall. This can result in damage to persons, machines and the device.
Secure the device against dropping during the entire installation.
1. Insert the device with its mounting seal, clamping frame and all enclosed mounting clips into
the mounting cut-out from the front, as shown in the figure.
The tip of the setscrew must be inserted into the center hole as shown in the zoomed section
of the figure.
Material thickness t at the
mounting cutout:
2. Turn the setscrew of each mounting clip until a slight clamping force is perceptible.
After a few rotations a slight resistance will become perceptible. When the increase in force is
perceptible, tighten the setscrew of the next mounting clip. Perform this step for all setscrews.
3. Check that the mounting seal is properly seated.
– The edge of the mounting seal must be flush and evenly flush with the stainless steel front
on all sides.
– The edge may protrude 0.1 to 0.5 mm.
4. Tighten the setscrew of the mounting clip until the fixed stop is reached and the torque
increases perceptibly. The tightening torque is then:
– Approx. 1.0 Nm with 7", 9" and 12" devices
– Approx. 0.5 Nm with 15" and 19" devices
5. Check that the stainless steel front is in contact with the mounting location on all sides and
that the mounting seal is pressed against the surrounding area.
6. Check that the fixed stop has been reached on all mounting clips and that the mounting seal is
installed correctly. Correct the tightening torque, if necessary, so that the clamping force is
-
.
evenly distributed.
Removal
For removal, follow the steps for installation in reverse order. Dispose of the used mounting seal.
Technical Support
Technical support for the devices described in this document is available at: Technical Support
(https://support.industry.siemens.com)
Siemens AG
Division Digital Factory
Postfach 48 48
90026 NÜRNBERG
GERMANY
TP700/900/1200 Comfort INOX: 1.5 ... 6 mm
TP1500/1900 Comfort INOX and ITC1900 INOX: 1.5 ... 5 mm
Comfort Panels INOX, ITC INOX