Herunterladen Inhalt Inhalt Diese Seite drucken

Electric Connection - JETStream TREVI Montage- Und Bedienungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
3
(230 V)
When the pump is full (volume approx. 8.5 l) water does not overflow but flows back into the
swimming pool through the nozzle.
Screw in the screw plug (8) and washer and screw tight.
Fit the cover (5) (supplied separately). On the inside of the cover there is a holding band (15). Pull the free end of
the holding band through, under the pressure plate (14) which is on the base plate. Screw in both the Phillips
screws of the pressure plate.
The cover must be fastened securely to the base plate via the holding band. Secure the cover (5) using the four
fastening screws (13).
The unit has a safety switch and can be started only once the cover (5) has been fitted.
If the pump fails to pump water after the first attempt to start it, you must re-fill the pump with
water (there is still air in the pump housing). You must continue to fill the pump until the nozzle
has its full power.

5 ELECTRIC CONNECTION

5.1 Electric Connection
All connection work must be performed carefully according to the regulations DIN VDE 0100
Part 702. The safety instructions and requirements of uwe and the other manufacturers and
authorities involved must be observed.
All work on stationary swimming pool pumps must only be performed by companies authorised by uwe and by
trained electricians. The DIN VDE and applicable regulations for the prevention of accidents must be observed for
all work with voltages.
The unit is shipped with an 8 m (TREVI 230 V) or 10 m (TREVI 400 V) long, weather-resistant power supply cable
and outlet box. For the power supply to the permanent connection, a cable cross-section of 3 G 2.5 mm
for TREVI 230 V and H07 5 G 2.5 mm
shock with protective earthing DIN VDE 0100 Part 702 and by connecting a circuit-breaker FI≤30 mA. In the
protection zone 0 and 1 to DIN VDE, the connecting cable must be laid in a plastic pipe or directly in the walkway
behind the pool wall.
The powerful single-phase motor (TREVI 230 V) or three-phase motor (TREVI 400V) is secured below the cover
which is mounted on the edge of the pool. This motor is separated from the water-guiding parts of the pump. All
foreign conductive parts in the areas 0.1 and 2 must be included in the additional, local equipotential bonding.
This additional, local equipotential bonding must be connected to the PE conductors of the bodies in these areas.
In addition, please refer to the "Information for the Electrician".
min. 20
Measurements in mm
2
for TREVI 400 V is required, respectively. The unit must be protected against
3
(400 V)
17
The machine should not
be run without water.
min. 20
Measurements in mm
2
(L,N,PE)

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Trevi lux

Inhaltsverzeichnis