Herunterladen Inhalt Inhalt Diese Seite drucken

Installation In In-Ground Pools - JETStream TREVI Montage- Und Bedienungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
1
(230 V)
rubber buffer
55
min. 20
4.2 Installation in In-Ground Pools (please unfold the last page, Fig. 1)
Remove the retention pins (1) by turning anticlockwise. These are not required for in-ground pools.
Place the unit at the edge of the pool in the position you require.
The unit must be horizontal, support if necessary.
Positioning the Nozzle
Adjust the height of the nozzle (2) to the water level. To do this, unscrew the hexagon nuts (3) and move the
nozzle either up or down to the correct height.
The nozzle must be 20 cm below the water level. The distance from the edge of the pool down
to the water level must not exceed 27 cm.
Further Installation
Secure the unit together with the rubber buffer (4) to the pool wall.
The gap between the pool wall and the back of the housing submerged in the water must be at
least 20 mm. Extensions are available.
Mark the 4 mounting holes on the outer edge of the base plate (6) which are now accessible. Fix the unit in place
with the M 8 x 60 screws.
The base plate must be level and must not be bent out of shape. Support if necessary.
Unscrew the screw plug (8). Slowly fill the pump with water.
When the pump is full (volume approx. 8.5 l) water does not overflow but flows back into the
swimming pool through the nozzle.
Screw in the screw plug and washer and screw tight. Fit the cover (5) (supplied separately). On the inside of the
cover there is a holding band (15). Pull the free end of the holding band through, under the pressure plate (14)
which is on the base plate. Screw in both Phillips screws of the pressure plate. The cover must be fixed securely
to the base plate via the band. Secure the cover (5) using the 4 fastening screws (13).
The unit has a safety switch and can only be started once the cover (5) has been fitted.
If the pump fails to pump water after the first attempt to start it, you must re-fill the pump with
water (there is still air in the pump housing). You must continue to fill the pump until the nozzle
reaches its full power.
Measurements in mm
1
(400 V)
15
min. 20
Measurements in mm