Select the display unit (Uni) before you define the values for the para-
meters SP1, SP2, ASP, AEP. This avoids rounding errors during internal
conversion to other units and enables exact setting of the values.
When delivered: mm.
If no button is pressed for 15 s during the setting procedure, the unit
returns to the Run mode with unchanged values.
The unit can be electronically locked to prevent unwanted adjustment
of the set parameters: Press the two programming buttons in the Run
mode until
is displayed.
On delivery: Unlocked.
When the unit is locked,
change parameter values.

Set-up / Operation

After mounting, wiring and programming check whether the unit ope-
rates correctly.
Align the unit (laser beam) to the object to be detected. If correctly set
up, the distance to the object is indicated.
Faults displayed during operation:
++
--
far
near
SC1
SC2
SC
Life of the laser diode: 50 000 hours.
Downloaded from
www.Manualslib.com
is displayed. For unlocking press the buttons until
too much light, e.g. reflective surfaces
not enough light
measured object outside the measuring range > 10m
measured object outside the measuring range < 0.2m
short circuit in switching output 1
short circuit in switching output 2
short circuit in both switching outputs