Technical Data

EN
The following table lists input values for the appliance.
Burner
Main
Side
Certified Gases / Pressures - Check rating plate to ensure that it corresponds with following list.
Gas Category
Orifice Sizes
(see above)
Gases /
Pressures
Countries
Do not tamper with or modify regulator. Use only regulator which supply the pressure listed in the table
above. A regulator of 28 – 30 mbar must be used for butane or a 37 mbar regulator for propane.
For replacement, use only the regulator specified by the manufacturer.
The regulator cannot be adjusted. There is a pressure tap located on the side of the regulator. It can be
used by a qualified service person when servicing the grill to determine if the regulator is functioning
properly. The screw within the pressure tap must always be kept tight, except when performing a pressure
test on the regulator (qualified service personnel only).
Leak Testing Instructions
!
WARNING!
part of the gas system is replaced.
!
WARNING!
are in the area while you check for leaks. Sparks or open flames will result in a fire or explosion,
damage to property, serious bodily injury, or death.
Leak testing: This must be done before initial use, annually, and whenever any gas components are
replaced or serviced. Do not smoke while performing this test, and remove all sources of ignition. See Leak
Testing Diagram for areas to check. Turn all burner controls to the off position. Turn gas supply valve on.
Brush a half-and-half solution of liquid soap and water onto all joints and connections of the regulator,
hose, manifolds and valves.
Bubbles will indicate a gas leak. Either tighten the loose joint or have the part replaced with one
recommended by the Napoleon Customer Solutions department and have the grill inspected by a certified
gas installer.
STOP
If the leak cannot be stopped, immediately shut off the gas supply, disconnect it, and have the grill
inspected by a certified gas installer or dealer. Do not use the grill until the leak has been corrected.
www.napoleon.com
N415-0401CE-GB-DE MAR 12.19.indd 6
Orifice Size
0.99mm (30mbar)
0.92mm (37mbar)
0.84mm (50mabr)
0.92mm (30mbar)
0.86mm (37mbar)
0.80mm (50mabr)
I
I
3B/P(30)
3+(28-30/37)
I
Butane 30mbar
Butane 28-30mbar
Propane 30mbar
Propane 37mbar
BE, BG, CY, DK, EE, FI,
BE, CH, CY, CZ, ES, FR,
FR, GB, HR, HU, IS, IT,
GB, GR, IE, IT, LT, LU,
LT, LU, MT, NL, NO,
LV, PT, SK, SI
RO, SE, SI, SK, TR
A leak test must be performed annually and each time a cylinder is hooked up or if a
Never use an open flame to check for gas leaks. Be certain no sparks or open flames
(Gross) Heat Input (Total)
8.0 kw
8.0 kw
8.0 kw
3.5 kw
3.5 kw
3.5 kw
I
3B/P(37)
I
I
Butane 37mbar
Propane 37mbar
PL
Gas Usage (Total)
580 g/hr
580 g/hr
580 g/hr
254 g/hr
254 g/hr
254 g/hr
I
3B/P(50)
I
Butane 50mbar
Propane 50mbar
AT, CH, DE, SK
N415-0401CE-GB-DE MAR 12.19