For the best results, a target should have to move across the coverage area. Note
how the zones are spaced wider near the end of the sensors range, and are shorter
at the edges of the coverage area. At the far end of the detection area the sensor is
covering the largest number of area. As you move closer to the sensor its coverage
area decreases.
Ӽ How to Test?
Please conduct a walking test after installing the device onto a wall to ensure
the device is functioning. Please check before the test (example based on
"AND" mode. ) :
- DIP1 & DIP5 switches are switched to "On";
- Ensure all wiring is correct;
Downloaded from
www.Manualslib.com
Step 1. When power is on, please wait for approxi-
mately 1 minute for the device to finish self-inspec-
tion (red LED will stop flashing once done) and for
the sensors to warm up. When moving within the
detection area, the red LED will light up and signal
a detection if both sensors detected you. After 2s of
no movement, the LED will turn off. Wait for 15s
for the sensors to become active again.
Step 2. Now walk to the edge of the detecting area,
check the LED status. The blue LED will be on if
you are within the PIR detecting area and it will
flash if you are in the microwave detection area.
Step 3. Repeat step 2 on all edges of the detection
area to see if it covers your required area. The red
LED has to light up in order to signal you that both
the PIR and Microwave sensor detected you.
Step 4. You may adjust the Microwave strength
clockwise to strengthen the sensitivity - if required.
manuals search engine
10
-EN