Troubleshooting

IMPORTANT!
In the event of problems and in finding their causes, the applicable safety regulations must be observed.
Problems
Pilot light does not go on
Pilot light goes out
Burner does not ignite
Should disruptions/defects arise that are not mentioned in this manual, please contact our customer service team by
using the contact information on page 45.
V1/2020_EM/CZGB-S
Possible causes
Gas valve may be closed
Fuel cylinder empty
Opening blocked
Air in feed
Battery empty
Loose connection
Dirt around the pilot light assembly
See also "Operating for first time" on page 40.
Defective heating element
Leak in gas line
Low gas pressure
Opening blocked
Regulator is not turned on
Pilot light assembly is bent or not in the
proper position
Solutions
Open gas valve
Fill LPG cylinder
Clean or replace opening
Remove air from lines
Replace battery with same type
Check all connections and tighten if
necessary
Clean the dirty area
Replace heating element
Check connections
Gas tank is almost empty
Remove, clean and reattach
Turn valve to ON
Position the pilot light assembly correct-
ly and try again