BTL6-E500-M _ _ _ _ -E2-SA313-LA00,19-ZA0T
Micropulse AT transducer in round profile housing
Installation
NOTICE!
Interference in function
Improper installation can compromise the function of the
transducer and result in increased wear.
The mounting surface of the transducer must make
full contact with the supporting surface.
The bore must be perfectly sealed (O-ring/support
ring).
The BTL transducer can be fastened in a fitting bore
(Ø 48 H8), but must be sealed with the provided O-ring
and support ring.
The body of the transducer is fastened using 3 M5
threaded pins at a 120° angle.
If installing horizontally with nominal lengths > 500 mm,
we recommend tightening the outer rod at the end or
supporting it.
If installed in a hydraulic cylinder, the magnet should not
make contact with the outer rod. Minimum bore diameter
in the support piston:
Tube diameter
10.2 mm
Shielding and cable routing
Defined ground!
The transducer and the control cabinet must be
at the same ground potential.
Shielding
To ensure electromagnetic compatibility (EMC), observe
the following:
Install transducer in a closed and grounded metal
housing.
Magnetic fields
The position measuring system is a magnetostrictive
system. It is important to maintain adequate distance
between the transducer cylinder and strong, external
magnetic fields.
Cable routing
Do not route the cable between the transducer, controller,
and power supply near high voltage cables (inductive stray
noise is possible).
The cable must be routed tension-free.
2
english
Bore diameter
At least 13 mm
Startup
DANGER
Uncontrolled system movement
When starting up, if the position measuring system is
part of a closed loop system whose parameters have not
yet been set, the system may perform uncontrolled
movements. This could result in personal injury and
equipment damage.
Persons must keep away from the system's
hazardous zones.
Startup must be performed only by trained technical
personnel.
Observe the safety instructions of the equipment or
system manufacturer.
1.
Check connections for tightness and correct polarity.
Replace damaged connections.
2.
Turn on the system.
3.
Check measured values and adjustable parameters
regularly (especially after replacing the transducer or
after repair by the manufacturer).
Operating notes
Check the function of the transducer and all associated
components on a regular basis.
Take the position measuring system out of operation
whenever there is a malfunction.
Secure the system against unauthorized use.