Herunterladen Diese Seite drucken

Balluff BTL6-E500-M E2-SA313-LA00,19-ZA0T Serie Kurzanleitung Seite 4

Micropulse wegaufnehmer

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

BTL6-E500-M _ _ _ _ -E2-SA313-LA00,19-ZA0T
Micropulse AT transducer in round profile housing
EU Directive 2004/108/EG (EMC Directive) and EMC law
Noise immunity: EN 61000-6-1/EN 61000-6-2
Emission: EN 61000-6-3/EN 61000-6-4
Intended use
The BTL6 Micropulse Transducer, together with a machine
controller (e.g. PLC), comprises a position measuring
system. It is intended to be installed into a machine or
system. Flawless function in accordance with the
specifications in the technical data is ensured only when
using original BALLUFF accessories. Use of any other
components will void the warranty.
Opening the transducer or non-approved use are not
permitted and will result in the loss of warranty and liability
claims against the manufacturer.
General safety notes
Installation and startup may only be performed by
trained specialists.
The operator is responsible for ensuring that local safety
regulations are observed. In particular, the operator must
take steps to ensure that a defect in the position
measuring system will not result in hazards to persons or
equipment.
If defects and unresolvable faults occur in the transducer,
it should be taken out of service and secured against
unauthorized use.
EMC characteristics can only be ensured if the
BTL6-E... is completely installed in a grounded
metal housing.
25.2
21
~190
7
45°
4
7.5
www.balluff.com
Mounting
surface
30
-1
Nominal length =
Measuring range
1)
2)
Magnet
Ø 24
25
O-ring
Support ring
Downloading further instructions
A complete standard user's guide can be downloaded
from the Internet at www.balluff.com/downloads-btl6
or requested via e-mail from service@balluff.de.
See the user's guide for information on
standard/additional regulations or compatibility
tests for the BTL6.
Dimensions and function
The transducer contains the waveguide. A magnet is
moved along the waveguide. This magnet defines the
position to be measured on the waveguide.
Electrical connection
Color
GN green
BN brown
BU blue
1) Unassigned leads can be connected to GND on the controller side but
not to the shield.
2) Reference potential for supply voltage and EMC-GND.
1)
Damping zone
63.5
Thread
Ø 10.2
M4x4/6 deep
1)
Unusable area
2)
Not included in scope of delivery
File no.
E227256
BTL6-E...
4...20 mA 1)
10 to 30 V
GND 2)
Ø 48 f7
Ø 38.9
english
1