Installation of the pH Perfect on the filtration system
!
The distance between the sensor and the injection point must not be less
than 60 cm.
The injection point must be the last element on the return line before the pool.
Keep the sensor cable away from other power cords in order to prevent electrical
interference.
The maximum pressure in the pipes must not exceed 150 kpa.
To increase the life span of the peristaltic pipe, the pressure should not exceed
100 kpa.
If the pool has a chlorinator, a heating system or any other equipment, they must
be situated after the pH sensor but before the acid injection point.