Herunterladen Inhalt Inhalt Diese Seite drucken

Adjustable Parameters; Operation - IFM Electronic ecomot200 Compact M18 Montageanleitung

Drehzahlwächter
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

4. Adjustable parameters

Setting
Switch point (= teach value x 0.8)
Start-up delay
Output function
Locking
5. Setting operation
Time period
Duration [s]
= Press the button and keep it pressed
= Release the button = Setting stored
= Release the button and press n times (0 times = 0 s, 1 time = 1 s, etc.)
The setting operation is divided into time periods with a duration of approx. 3 and
5 seconds. The corresponding setting is stored within a time period by releasing
the pressed button. The time periods are indicated by different flashing frequencies
of the "DMP" LED.
Time period
1
2
3
4

6. Operation

The operation is maintenance-free. Ensure the following for a correct function:
• Keep the sensing face and the open space free of metal deposits and foreign
bodies.
• Do not operate units with a high near field strength (e.g. radio equipment) in
the immediate vicinity of the speed monitor.
Downloaded from
www.Manualslib.com
Function
teach the switch point
set the start-up delay
change the output function
(no
nc, nc
no)
lock or unlock the settings
manuals search engine
Value range
SP
3...6000 pulses/min.
t
0...15 s
Output
NO/NC
Key
on/off
To store:
release the button
release the button
press the button n times,
wait 5 s after the last push of the button
release the button
release the button
COMPACT SPEED MONITOR
Factory setting teach value
100 pulses/min.
10 s
NO (output closed when
speed > switch point)
off
M18
5

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Ecomot200 di6001

Inhaltsverzeichnis