COMPACT SPEED MONITOR
1. Function and features
The unit detects without contact if a set rotational speed is exceeded or not rea-
ched and signals this by means of a switched output. The pulse output enables the
external evaluation of the damping pulses.
Nominal sensing range (S
2. Mounting and electrical connection
Fix the unit by means of a mounting fixture and protect it against loosening by
means of the enclosed nuts. Not flush mountable.
Adhere to the above dimensions to ensure a correct function.
The unit must only be connected by a qualified electrician. Observe the na-
tional and international regulations for the installation of electrical equip-
ment. For the wiring please see the type label.
3. Operating and indicating elements
Press the button with a blunt object (e.g. pen).
4
Downloaded from
www.Manualslib.com
M18
) and operating voltage see type label.
n
LED
PWR
OUT
DMP
Set button
OUT +
DMP
manuals search engine
Status
green
ON
yellow
ON
green
pulse
1 Hz
2 Hz
double flash
yellow
flashing
green
alternately
2: pulse output
(pulse sequence corresponds
to the damping frequency)
4: switching output
(adjustable)
Meaning
operating voltage ok
output is switched
damping pulse
time periods during
the setting operation
(see 5, setting operation)
settings locked or setting
not accepted