Herunterladen Inhalt Inhalt Diese Seite drucken

Battery Maintenance; Battery Charging - Upright MX19 Betriebsanleitung

Vorschau ausblenden Andere Handbücher für MX19:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 20
Maintenance
B
B
NOTE: The battery charger circuit must be used with a GFI (Ground Fault Interrupt) outlet.
NOTE: DO NOT operate the machine while the charger is plugged in.
Operation Manual
Downloaded from
www.Manualslib.com
M
A T T E R Y
A I N T E N A N C E
W A R N I N G
!
Hazard of explosive gas mixture. Keep sparks, flame, and smoking material away from batteries.
Always wear safety glasses when working near batteries.
Battery fluid is highly corrosive. Thoroughly rinse away any spilled fluid with clean water.
Always replace batteries with UpRight batteries or manufacturer approved replacements weighing
26,3 kg (58 lbs.) each.
• Check the battery fluid level daily, especially if the work platform is being used in a warm, dry climate.
• If electrolyte level is lower than 10 mm (
tap water with high mineral content, as it will shorten battery life.
• Keep the terminals and tops of the batteries clean.
• Refer to the Service Manual to extend battery life and for complete service instructions.
C
ATTERY
HARGING
Charge the batteries at the end of each work
shift or sooner if the batteries have been dis-
charged.
W A R N I N G
!
Charge the batteries in a well ventilated area.
Do not charge the batteries when the work platform is near a source of sparks or flames.
Permanent damage to the batteries will result if the batteries are not immediately recharged after
discharging.
Never leave the battery charger operating for more than two days.
Never disconnect the cables from the batteries when the charger is operating.
Keep the charger dry.
1. Check the battery fluid level. If the battery fluid level is lower than 10 mm (
distilled water only.
2. Connect an appropriate extension cord to charger outlet plug in Left Module Door. Plug the extension
cord into a properly grounded outlet of proper voltage and frequency.
3. The charger turns on automatically after a short delay. The LED charge indicator will illuminate. After
completion of the charge cycle the LED will blink, indicating that the charger is in a continuing mainte-
nance mode. DO NOT leave the charger plugged in for more than 48 hours, as permanent damage to
the batteries may occur.
manuals search engine
!
3
in.) above the plates add distilled water only. DO NOT use
/
8
!
Figure 8: Battery Charger
Charger Outlet Plug
LED Indicator
in.) above the plates add
3
/
8
Page 13

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis