DANGER!
Electrical current! Risk of electric shock!
Be sure the electric apparatus is turned off
before plugging in.
Be sure the total load is within generator
rated output.
Be sure the socket load current is within
socket rated current
the economy control switch must be turned
to "OFF" when using electric devices that
require a large starting current, such as a
compressor or a submergible pump.
2. OVERLOAD INDICATOR LIGHT
the overload indicator light comes on when an
overload of a connected electrical device is detected,
the inverter unit overheats, or the ac output voltage
rises. the electronic breaker will then activate, stop-
ping power to the generation in order to protect the
generator and any connected electric devices. the
output pilot light (green) will flicker and the overload
indicator light (red) will turn on, then the engine will
stop running. If so please follow the following steps:
(a) turn off any connected electric devices and stop
the engine
(b) Reduce the total wattage of connected electric
devices within the application range.
(c) check for blockages in the cooling air inlet and
around the control unit. If any blockages are found,
remove.
(d) check if the air inlets and outlets, that are neces-
sary for the cooling of the generator, are clear.
after checking, restart the engine.
INFORmATION!
the generator ac output automatically
resets when the engine is stopped and then
restarted.
the overload indicator light may come on
for a few seconds at first when using electric
devices that require a large starting current,
such as a compressor or a submergible
pump. However, this is not a malfunction.
26
Downloaded from
www.Manualslib.com
manuals search engine
3. DC APPLICATION (option)
this usage is applicable to 12V battery charging only.
(a)
charging instruction for battery
Disconnect the leads for the battery.
Make the battery fluid filler cap loose fully.
Fill distilled water to the upper limit, if the
battery fluid is low level.
Measure the specific gravity for the battery
fluid by using the hydrometer, and calculate
the charging time in according with the table
shown on right side.
(b) connect between the Dc output socket and the
battery terminals using the charging leads. the leads
shall be connected making sure of the (+) and (-)
polarity
(c) plug the 2-pole plug of the 12V charging cable
into the 12V socket.
(d) connect the minus terminal (black) to the minus
pole of the battery.
(e) The DC circuit protector is to be set to "ON" after
confirming the connection, if the protector is in "OFF"
position.
ATTENTION!
Be sure the economy control switch is turned
"OFF" while charging the battery.
Aim for specific gravity and charging time
1.30
1.26
1.22
1.18
1.14
1
1.10
1.06
0
2
4
chargong time Hr
Battery capacity
1. 30AH 20HR
2. 35AH 20HR
3. 47AH 20HR
For disconnecting the battery, proceed as follows:
(a) Disconnect the minus terminal (black) from the
minus pole of the battery.
(b)pull the 12V charging cable out of the generator.
(c) Disconnect the plus pole terminal (red) from the
plus pole of the battery.
2
3
6
8
10