Herunterladen Diese Seite drucken

Herth+Buss PlusMinus multi Bedienhinweis Seite 13

Spannungs-/strom-meßgerät

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Operating Instruction
The component has a short circuit or is

directly connected to earth/the negative
terminal.
The component's current consumption is

too high (above 8 A).
NOTE
When triggered, the device's

short-circuit protection will be au-
tomatically deactivated again after
max. 60 seconds
herthundbuss.com/Online-Katalog
Activating components with positive
voltage
When the technician is testing the compo-
nents, they can use the multi-function test
lamp to supply the tested components with
positive voltage. To do so, proceed as follows:
1. Apply the probe to the positive terminal of
the component. If the green LED lights up,
the tested component is conductive.
2. If the green LED lights up, please push the
polarity switch forwards and then release
it again shortly afterwards.
13
If the LED switches from green to red, the
test can be resumed. If the green LED goes
out and the red LED lights up or the short-cir-
cuit protection is triggered, the multi-func-
tion test lamp is overloaded. The causes of
this may be the following:
The component has a short circuit or is

directly connected to earth/the negative
terminal.
The component's current consumption is

too high (above 8 A).
NOTE
When triggered, the device's

short-circuit protection will be au-
tomatically deactivated again after
max. 60 seconds. herthundbuss.
com/Online-Katalog
Only execute this function while adhering to
schematic and correct test procedures. Ran-
dom application of voltages may destroy the
component or circuit being tested.