Technical data

Rated operating voltage U_b
Operating voltage range
Current consumption at U_b=12V DC:
Evaluation unit
Per sensor
Per LED
Transmission and control functions
Disarmed
Clear function
Alarm
Tamper
Sensor connections
IDENTLOC
Conventional
Display functions
visible from outside
in the housing
Frequency range
Transmission power
Protection class as per DIN 60529
Environmental class as per VdS
Operating temperature range
Storage temperature range
Dimensions (WxHxD)
Color
Hereby, the Novar GmbH declares that the radio equipment IDENTLOC evaluation unit Item no. 032211.17 is in
compliance with Directive 2014/53/EU.
The full text of the EU declaration can be downloaded from our homepage https://www.security.honeywell.de/ in the service/
download area.
EU BUS-2/BUS-1
Item
no. 032211.17
12 V DC
9 V to 15 V DC
£
12 mA
£
3 mA
£
1.3 mA
via BUS
via BUS
via BUS
via BUS
4 connectible transmission units
1 diff. detector group
with clear function
1 totalling LED
1 teaching mode LED
1 LED per sensor
with diagnosis function
125 kHz
no transmission power
IP 40
II
-5 °C to +45 °C
-25 °C to +70 °C
118 x 118 x 31 mm
Traffic white
(similar to RAL 9016)