7.

Stand alone programming mode

To program in this mode, only the 12 V DC operating voltage is required.
7.1

Activate programming mode

Press the 3 keys (with the symbols as shown) simultaneously and keep
pressed. Apply the operating voltage. As soon as the programming
mode is activated, the three LEDs flash every second. Release keys.
7.2

Clear address

Activate
key "1"
to clear an already allocated address.
7.3

Load standard values

Activate
key "2"
to create the condition on delivery:
-
Range:
-
Illumination:
-

Transponder detection:

An already allocated address is not altered.
7.4

Adjustment mode - range

Activate
key "3"
to activate the adjustment mode. Adjustment is described in detail in Chapter 6.4.
Activate
key "3"
again to exit the adjustment mode.
7.5

Keypad lighting

In its state at the time of delivery, the illuminated no-load status (no operating procedure) is
switched off. It is activated and lit up fully only for 5 seconds if a button is pressed or a transponder
is held in the reading range.
If you require permanent illumination, the brightness for the no-load status can be set in steps
using button "4" and "5". This does not affect the full brightness during operation.
Button "4":
Every time the button is activated, the illumination becomes gradually darker until it is
fully switched off.
Button "5":
The brightness increases in steps until it reaches maximum brightness.
The set value is permanently saved when the programming mode is exited.
7.6
Transponder detection
In its state at the time of delivery, the antenna is actuated in cycles (60 ms active, 300 ms pause) to
achieve medium current consumption. In certain cases this may result in the transponder not being
fully identified the first time it is held in the reading range.
Button "8":
The antenna is permanently activated using button "8".
Button "7":
re-establishes the state at the time of delivery (cyclical actuation).
7.7

Exit programming mode

Press key "X" to exit programming mode.
Mounting and Operating Instructions - proX2-reader "Accentic" with keypad
³6 cm with ID cards
no-load status when no operation
cyclical actuation (low current mode)
i