7

Technical data

Parameters for VT LP04 AS-i

General
Protection class according to
EN 60 529/ IEC 529
Ambient temperature
Electrical data
Operating voltage on AS-i
Operating voltage on AUX
Current per valve solenoid
Inputs according to DIN EN 61131-2
Input delay 0-1/1-0
Power supply for sensors per M12
Electromagnetic compatibility
Interference immunity
Interference signal

Accessories for VT LP04 AS-i

Description
8-pin connecting cable 2 x M12 f/m
8-pin connecting cable 2 x M12 f/m
8-pin connecting cable 2 x M12 f/m
8-pin connecting cable 2 x M12 f/m
8-pin connecting cable 2 x M12 f/m
M12 protective cap connector
Input module 3-pin 4 x M8 + 8-pin M12
AS-i cable connector
Downloaded from
www.Manualslib.com
IP65 when assembled
0°C to +50°C without condensation
U
n
EN 50295
U
n
according to IEC 364-4-41
Residual ripple 0.5%
30 mA
0/4/8 digital inputs, type 1
3 ms
Max. 150 mA
EN50295
EN50295
manuals search engine
AVENTICS | LP04 | R402001614–BDL–001–AC
26,5 V to 31,6 V DC in accordance with
24 V DC (+10%/–10%) Protective extra low voltage (PELV)
Cable length
straight 0,5 m
straight 1 m
straight 2 m
straight 5 m
straight 10 m
15
Material nummer
8946202802
8946202812
8946202822
8946202832
8946202842
8941350294
R402001810
8941053572

Werbung