Herunterladen Inhalt Inhalt Diese Seite drucken

Siemens SITRANS Probe LR Kurzanleitung Seite 149

Vorschau ausblenden Andere Handbücher für SITRANS Probe LR:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 31
Apparatens märkskylt (FM)
SITRANS Probe LR
7MLxxxx-xxxxx-xxxx
Serial No: GYZ / S1034567
Encl.: NEMA / TYPE 4X, 6, IP67, IP68
Amb.Temp.: – 40 °C to 80 °C
Power Rating: 24V
FM Egensäker anslutning ritning nummer A5E01003040 kan laddas ner från produktsidan på
vår webbsida: www.siemens.com/probelr. Gå till Support > Installation Drawings
(Installationsritningar) > Level Measurement (Nivåmätning) > Continuous – Radar
(Kontinuerlig – Radar).
Apparatens märkskylt (CSA)
SITRANS Probe LR
7MLxxxx-xxxxx-xxxx
Serial No: GYZ / A1034567
Encl.: NEMA / TYPE 4X, 6, IP67, IP68
Amb.Temp.: – 40 °C to 80 °C
Power Rating: 24V
CSA Egensäker anslutning ritning nummer A5E01003039 kan laddas ner från produktsidan på
vår webbsida: www.siemens.com/probelr. Gå till Support > Installation Drawings
(Installationsritningar) > Level Measurement (Nivåmätning) > Continuous – Radar
(Kontinuerlig – Radar).
• För kabeldragningskrav: följ lokala bestämmelser.
• Godkända dammtäta och vattentäta kanaltätningar krävs utomhus typ 4X / NEMA 4X,
• Se
• För effektbehov se
2. Icke antändlig kabeldragning (endast FM/USA)
SITRANS Probe LR
7MLxxxx-xxxxx-xxxx
Serial No: GYZ / S1034567
Encl.: NEMA / TYPE 4X, 6, IP67, IP68
Amb.Temp.: – 40 °C to 80 °C
Power Rating: 24V
FM Klass 1, Div 2 anslutningsritning nummer 23650537 kan laddas ner från produktsidan på
vår webbsida: www.siemens.com/probelr. Gå till Support > Installation Drawings
(Installationsritningar) > Level Measurement (Nivåmätning) > Continuous – Radar
(Kontinuerlig – Radar).
• För effektbehov se
A5E32106153
Downloaded from
www.Manualslib.com
6.3 GHz
Nom., 30 V
Max., 4 - 20mA
Siemens Milltronics Process Instruments, Peterborough
Assembled in Canada with domestic and imported parts
6.3 GHz
Nom., 30 V
Max., 4 - 20mA
Siemens Milltronics Process Instruments, Peterborough
Assembled in Canada with domestic and imported parts
typ 6 / NEMA 6, IP67, IP68 platser.
Instruktioner som gäller installation på riskabla platser (Referens: Europeiska ATEX-
direktivet 94/9/EG, Bilaga II, 1/0/6)
Loop power
6.3GHz
Nom., 30 V
Max., 4 - 20mA
Siemens Milltronics Process Instruments, Peterborough
Assembled in Canada with domestic and imported parts
Loop power
SITRANS Probe LR – SNABBSTARTSMANUAL
manuals search engine
Class I, Div 1, Group A, B, C, D
Class II, Div 1, Group E, F, G
Class III
Temp. Code: T4
FM per drawing A5E01003040
This device complies with Part 15 of the FCC Rules. Operation is subject to the
following two conditions 1)This device may not cause harmful interference and
HART
2)This device must accept any interference received, including interference that
may cause undesired operation
WARNING: Possible Static Hazard, Do Not Rub Or Clean On Site.
Class I, Div 1, Group A, B, C, D
Class II, Div 1, Group E, F, G
Class III
Temp. Code: T4
CSA per drawing A5E01003039
HART
IC: 267P - LR200
WARNING: Possible Static Hazard, Do Not Rub Or Clean On Site.
på sida 8.
på sida 4 Bilaga A.
Class I,Div.2,
Group A,B,C,D
HART
Temp.Code:T5
på sida 4 Bilaga A.
Vmax = 30 V
Ci = 15 nF
Imax = 120 mA
Li = 0.1 mH
Pmax = 0.8 W
FCC ID: NJA-LR200
Vmax = 30 V
Imax = 120 mA
Pmax = 0.8 W
Ci = 15 nF
Li = 0.1 mH
159134
FCC : NJA–LR200
This device complies with Part 15 of the FCC Rules.
Operation is subject to the following two conditions
1)This device may not cause harmful interference and
2)This device must accept any interference received, including
interference that may cause undesired operation
Sida SV-7

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis