Herunterladen Inhalt Inhalt Diese Seite drucken

Cleaning Instructions; Storage And Transportation; Technical Specification - 3M G22 Bedienungsanleitung

Industrieschutzhelme
Vorschau ausblenden Andere Handbücher für G22:
Inhaltsverzeichnis

Werbung

and conditions of use. The key factors for a helmets 'in use' life are exposure to external force, chemicals and
^ The 3M™ UVicator™ and the helmet must be equally exposed to light. The 3M™ UVicator™ disc must
not be covered by stickers or removed from the helmet.
Electrically Insulating Helmets
The double triangle marking on the helmet indicates that the helmet is suitable for live working. The helmet provides
electrical insulation for use in low voltage installations up to a nominal value indicated next to the double triangle
symbol. Helmets approved according to EN50365:2002, class 0, makes them suitable for use in low voltage
necessary to use other insulating protective equipment according to the risks involved in the work. The user has to
check that the electrical limits of the helmets correspond to the nominal voltage that it is likely to encounter during
use. Insulating helmets should not be used in situations where there is a risk which could partially reduce its
limit the effectiveness of this product. When not in use it is recommended that the helmet should be stored in the
cleaned in accordance with the instructions below.
SPARE PARTS
ACCESSORIES

CLEANING INSTRUCTIONS

The helmet, head harness and sweatband should be cleaned regularly using a mild solution of detergent in warm
water.

STORAGE AND TRANSPORTATION

cool, dark location to prevent the material from ageing. The original packaging is suitable for transporting the
MARKING
/
Electrically insulating to EN50365:2002
{
?
See instructions for use.
^
Warning triangle

TECHNICAL SPECIFICATION

Material
[
Temperature Range
@
Maximum Relative Humidity
J
15

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

G2000G2001G3000G3001H700H701

Inhaltsverzeichnis