3. OPERATING INSTRUCTIONS
Proper Use
This product may only be used for the purposes specified in the catalogues and the technical descrip-
tions, i.e. to clean items specified in this operating manual, and only in conjunction with third-party
equipment and components recommended or approved by EMAG AG. Any other or additional use shall
be deemed not to be in accordance with its intended purpose. In case of improper use, EMAG AG assu-
mes no liability for any damage that may occur. The proper use also includes observing all instructions
in the operating instructions. This is indicated by the symbol
operation of the product requires proper transport, proper storage, installation and assembly as well as
careful operation and maintenance. The recurring tests according to DGUV V3 must be observed. The
device must be installed in such a way that the power plug is freely accessible at all times.
Improper Use
Attention! Please use this product only to clean items specified in this manual. The ultrasonic
cleaning device should only be used in conjunction with third-party devices and components
recommended or approved by EMAG AG.
If the product is used in a manner that is contrary to its intended purpose, risks to life and limb as well
as damage to property can occur. For this reason, improper use is prohibited. In case of improper use,
EMAG AG assumes no liability for any damage that may occur. In order to prevent the use of the ultraso-
nic cleaning device in violation of its intended purpose, the following instructions must be observed:
• The ultrasonic cleaning device may only be operated with the power voltage printed on the type
plate located on rear panel of the housing, in a grounded electrical socket.
• Do not use flammable or aggressive chemicals (i.e. acids etc.) for operation of the equipment. If neces-
sary, use glass container EM 50 DG.
• Do not touch the cleaning fluid during ultrasonic cleaning.
• If transport damage is detected, do not connect the ultrasonic cleaning device to the power source.
• Do not clean organic creatures (i.e. fingernails, animals, etc.) in the ultrasonic cleaning device.
• The ultrasonic cleaning device must only be operated with the correct level of water (water up to
mark, about 1 cm below the upper edge). This must be checked regularly for longer operating times.
• More heavily soiled items shall be positioned in the equipment with the soiled side down and do not
stack.
• The material to be cleaned must not be placed directly on the bottom of the tub (use the hanging
basket).
• If the equipment is to be operated for a longer time, do not stay longer than 4 hours within a 1 m
distance of the equipment.
• The device may only be operated indoors and in a dry environment.
• It is normal that the top edges of the tub warm up during extended operation.
• Be sure to unplug the power cord before emptying the tub.
• Coated glasses should be cleaned with care in this ultrasonic bath. When cleaning other glasses,
the cleaning should be max. 60 seconds. If you have questions, please contact your optician.
Note: the formation of ultrasonic friction can cause the water to heat intensely. Heating up
without ultrasonic use, can cause discoloration of the tub and damage the heater. The heater may
only be used in combination with the ultrasound.
Onlineshop: ultraschall-welt.de
on the type plate. The correct and safe
11

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Emmi-05pEmmi-d21Emmi-07d

Inhaltsverzeichnis