Technical Specifications - FIESSLER RAZL-2CO Handbuch

Vorschau ausblenden Andere Handbücher für RAZL-2CO:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
People Counter RAZL-2CO (Translation)

12 Technical specifications

230 V AC
Connector
over 4 m long connection cable with safety plug
Switching output
Potential-free, 1 changeover contact via 4 m long connection cable
max. 250V AC / max. 12A / max 3000 VA
(optional)
Reflector pillar: 119,8 cm
Pillar height
Sensor pillar: 130 cm
Pillar width
9 cm without stand
Pillar depth
8,5 cm without stand
Stand
20 cm diameter
Reflector pillar: approx. 6.7 kg
Weight
Sensor pillar: approx. 7.5 kg
IP40
The pillars are intended for indoor use. If the pillars are used outdoors, protection against precipitation must be provided
IP protection class
by suitable methods.
Drops on the front sides of the pillars can lead to miscounts.
Maximum distance
2 m
between the pillars
Minimum detection
Persons from a height >1.20 m are detected.
height of persons
Operational readiness
after < 95 seconds
Configuration via
The sensor pillar provides a WLAN for mobile devices with web browser such as smartphone, tablet or notebook for con-
WLAN
figuration
WLAN Specification
2,4GHz Wireless LAN, 2,4 GHz IEEE 802.11 b/g/n Wireless LAN
iOS Safari 7.0-7.1 or later
Supported browsers
Chrome for Android 78 or newer
Firefox for Android 68 or newer
Pillar combination con-
The sensor pillars can be operated in combination. (1 master pillar and up to 5 slave pillars)
nection
Up to 5 further inputs and outputs are evaluated and controlled by the master pillar.
Fiessler Elektronik GmbH & Co. KG
Buchenteich 14, D-73773 Aichwald
-37-
Phone: +49 (0)711 - 91 96 97 - 0
Fax: +49 (0) 711 - 91 96 97 - 50
24.06.2020
Internet: http://fiessler.de
E-Mail: info@fiessler.de

Werbung