5 Description of the system configuration

Current number of persons
Start value for number of per-
sons after restart
Maximum number of persons
allowed
Difference to the maximum num-
ber of persons for re-activation
Acoustic alarm when the per-
mitted number of persons is
exceeded
Error tolerance time Adjust-
ment alarm in seconds
Error message type
Error reporting behaviour
Fiessler Elektronik GmbH & Co. KG
Buchenteich 14, D-73773 Aichwald
A correction of the current number of persons present can be entered here
For personal with access via another input that is not recorded, a start value can be entered here.
Enter the maximum number of persons allowed.
By default 1 person per 20 m² and available area 300 m²:
Input = 15 (300 / 20 = 15)
By default 1 person per 10 m² and available area 300 m²:
Input = 30 (300 / 10 = 30)
Number of persons who have to leave the room again after an overrun.
In rooms with several monitored entrances, several people can enter the room simultaneously. As a result, the
permitted number of persons can be exceeded, even though all sensor pillars at the inputs have signalled
green.
If the permitted number of persons is exceeded, an acoustic alarm can be given.
- Active
- Disabled
Here you can set the time after how many seconds a warning should occur according to the configured error
reaction.
The error tolerance time should be chosen so large that a person walking slowly through the column does not
cause an error reaction.
Normally it is not intended that persons stay in the area of the pillars for a longer time. An error reaction time of
30 s is recommended.
If people frequently stand in the area of the pillars, the fault tolerance time can be increased accordingly.
If a person stops between the pillars, or if the pillars are no longer aligned correctly, it is no longer possible to
detect the persons. The signal lamp flashes red with or without acoustic warning when the fault tolerance time
is reached.
- Signal lamp with acoustic warning
- Signal lamp
Should an error be signalled on all devices or only on the affected device.
- All devices
- Affected device