8. Slide shrinking tube large (120 mm) over hot-cold termination. Place in centre with
approximately 25 mm on each side over outer sheath of cable. Shrink to fit using hot
air gun (Picture 28 to 30)
Picture 22
Picture 25
Picture 28
9. Strip end of cold lead approximately 70 mm (Picture 31). Place shrinking tube short
black (50 mm) centred on stripped cable end and shrink to fit using hot air gun
(Picture 32). Use thin flat pliers to indent shrinking tube between conductors for
optimum fixation (Picture 33). Strip conductors 7 mm and crimp on wire end sleeves
(Picture 34 and 35). Cable Assembly is finished (Picture 36).
Picture 23
Picture 26
Picture 29
Picture 24
Picture 27
Picture 30