EN - Installation instructions
NOTE
Original language and translations
The original language of this document is German. All other languages are
translations.
NOTE
Read and keep instructions
Read this document before using the product for the first time and keep it in a
safe place for future reference!
This edition replaces all earlier versions.
The installation recommendations are based on the most favourable conditions.
FEIG ELECTRONIC GmbH does not assume any warranty for the faultless
function in an external system.
In particular, FEIG ELECTRONIC GmbH cannot be held liable for consequential
damages due to incorrect installations.
The manufacturer has carefully checked the device hardware and software as well
as the product documentation. Mistakes cannot be avoided completely and we will
always gratefully accept any information in this respect.
3.1
Safety instructions
WARNING
Follow the instructions!
Follow the instructions for all products used! Incorrect commissioning can lead
to electric shock and serious injuries!
Use The traffic detector TST SUVEK1/2 only for the intended purpose with
controllers from FEIG ELECTRONIC GmbH!
The installation, commissioning and replacement of the product may only be
carried out by qualified personnel with accident prevention training.
The device may not be used as a safety component as defined by the Machinery
Directive, the Construction Products Regulation or other safety regulations.
Systems posing a threat of danger require additional safety equipment.
Impermissible alterations and the use of spare parts and additional devices not
sold or recommended by the device manufacturer can result in fire, electric shocks
and injury. Such measures result in abrogation of the liability and void the
manufacturer guarantee.
The device is subject to the manufacturer's guarantee conditions valid at the time
of purchase.
The manufacturer will not accept any responsibility for incorrect manual parameter
settings performed on a device or the unsuitable use of a device.
Repairs may only be performed by the manufacturer.
Sensors
TST SUVEK1/2-A
TST_SUVEK12-A_Install_rev5_mul
Users of devices which come into contact with electrical voltage are required to
comply with the valid VDE regulations. In particular, however, without claim to
completeness, these are: VDE 0100, VDE 0550/0551, EN 60335 (VDE 0700), EN
60065 (VDE 0860), EN 50110 (VDE 0105) well as the fire and accident prevention
regulations DGUV.
Work performed on the device and in conjunction with its setup must be conducted
in accordance with the specifications of the national electrical regulations and local
regulations.
The user is responsible for ensuring that the device has been setup and connected
in accordance with the accepted national and local technical regulations applicable
in the land of use. Especial attention is to be paid to the dimensioning of cables,
fusing, earthing, cut-off, separation, isolation monitoring and over-current
protection.
Dispose of the product at the end of its service life in accordance
with the valid legal specifications.
3.2
Abbreviations and definitions
Abb./Fig.
Figure
Tab.
Table
Gate and barrier controller with integrated frequency
Controller (TST)
converter or reversing contactor for triggering a motor.
The qualified specialist have been informed concerning
possible dangers in case of improper behaviour by working
with electrical equipment. The qualified specialist is familiar
Qualified
with the necessary protective measures and devices.
specialists
Furthermore, through the specialists professional training
and experience as well as its contemporary professional
activity, the specialist has the necessary knowledge for
testing work equipment.
3.3
Product description
The induction loop detector TST SUVEK1/2 is a system for inductive detection of
vehicles with the following characteristic features:
evaluation of one (TST SUVEK1) or two (TST SUVEK2) induction loops
galvanic separation between loop and detector electronics
automatic alignment of the system after switch-on
continuous adjustment of frequency drifts
no mutual interference between loops due to multiplexing (TST SUVEK2)
sensitivity independent of loop inductivity
indication of occupied loops via LED
open collector outputs galvanically separated by optocouplers
indication of loop frequency via LED
optional diagnosis function with diagnostic device VEK FG2
Please refer to our manual "vehicle detection with the induction loop detector"
when planning or installing induction loops.
4 | 9
Lange Straße 4 | D-35781 Weilburg
Tel. +49 6471 3109-0 | Mail:
Pos : 22 /VTM/VEK Z ubehör/Ü bers chriften/--Ü2---- Besti mmungsgemäß er Gebrauch @ 6\mod_1560261017063_10021.doc x @ 79194 @ 2 @ 1
3.4
Intended use
The traffic detector TST SUVEK is an electronic sensor for the inductive detection
of vehicles. The expansion card is only allowed for use with controller by FEIG
ELECTRONIC GmbH.
Operation is only permitted with the following controllers:
CE
TST FUF2-A, -C, -F series
TST FU3F-AU, -CU, -FU series
TST FU3F-A, -C, -F series
TST FU3H-FU series
TST FUH2-C series
TST FU3H-F series
TST FUZ2-B, -C series
3.5
Technical data
Type
Value
Dimensions (LxBxH)
72.5 x 50 x 18 mm (without plug connector)
Equipment type
Plug-in module, Induction loop detector, 1 or 2
channels
Protection type
IP 00
Protection class
III
Power supply
24 VDC
Power consumption
max. 2 W
-20 °C – +70 °C
Operating temperature
-20 °C – +70 °C
Storage temperature
Humidity
max. 95 % (non-condensing)
Loops:
20 – 800 µH
inductivity range
75 – 400 µH
Inductivity, recommended
30 – 130 kHz, 2 levels
Frequency range
0.01 % – 0.27 % (f/f), 4 levels
Sensitivity
0.02 % – 0.54 % (L/L)
Hold time
5 minutes or infinite
Loop supply line
max. 100 m
Loop resistance
max. 20 Ohm (including cable)
Optocoupler output
45 V, 10 mA, 100 mW
Trigger delay
50 ms (TST SUVEK1)
100 ms (TST SUVEK2)
Signal duration
> 200 ms
FEIG ELECTRONIC GmbH
info@feig.de
UL
2019-10-14