If desired, repeat the operation for the other cooking zones.
Note: Each cooking zone can have a different Timer set;
on the display, (10), the countdown of the last selected
cooking zone will be shown for 10 seconds, after which the
countdown with the least remaining time will be shown.
When the timer has completed the countdown an acoustic
signal sounds (for 2 minutes, or stops by pressing any hob
key), while the display (10) flashes with the symbol "
Note: at the side of the cooking zone display, when the Timer
is in use, the symbol
(9) is displayed.
To switch off the Timer:
• select the cooking zone
• set the value of the timer to " " , with
Note: the function remains active if no other key is pressed
in the meantime.
Egg Timer
The Egg Timer function is a countdown independent of the
cooking zones (and the extraction zone). At the end of the set
time, the user is informed by way of an acoustic signal.
The Egg Timer is activated by pressing
Note : to regulate the Egg Timer function, follow the same
procedure as for the Timer function.
Power Limitation
The Power Limitation function allows the product's operation
to be set while limiting its power absorption to a maximum limit
of 3.1 kW.
Note : the limit must be set when the hob is off, without
pressing the
key, at the time of the hob's connection to
the electrical network, or when the electrical network itself is
reconnected, within the following 2 minutes.
To set the Power Limitation:
- press
- while still pressing
press and release
- a short acoustic signal will sound
- while still pressing
press and release
- it is now possible to release the key
- display (7) of the FL zone shows the symbols "C" and "0"
alternately to indicate that the limit can be set
".
(2-FL)
:
60
- display (7) of the RL zone shows the current setting**
0 = 7.4 KW
1 = 3.1KW
** by default, the limit is set to 7.4 KW
- to change the Power Limitation setting, press
- to save the selection, press
prolonged acoustic signal will sound to confirm the setting.
- press
to exit the function
.
(2-FL)
for 2 seconds; a