Herunterladen Inhalt Inhalt Diese Seite drucken

Sun SWB 340 Betriebsanleitung Seite 130

Inhaltsverzeichnis

Werbung

4
4
130
Downloaded from
www.Manualslib.com
A
P
7-4
B
Q
7-5
manuals search engine
User Code
Stop of the wheel when the wheel guard is lifted
during the measuring run
(Fig. 7-4) Select; (4), (A), (P),
Disabled
= Stop deactivated
THE WHEEL ROTATES WHEN THE WHEEL GUARD
IS OPEN.
MAKE SURE THAT THE WHEEL IS NOT BLOCKED
BY A TOOL OR SIMILAR ITEM.
WEAR SAFETY GOGGLES AND TIGHTLY FITTING
WORKING CLOTHES.
Enabled(*)
= Stop activated
After the confi rmation, this operating mode can
be acquired in the permanent memory (Fig. 7-6).
Number of revolutions per measuring run - 5 to 20
revolutions possible, factory–set to 10*
(Fig. 7-5) Select; (4), (B), (Q), (Q1),
Rotate the shaft to change the value.
Type on the value set.
S
Warning
Reducing the number of measurement revolutions will
reduce the accuracy of measurement.
After the confi rmation, this operating mode can
be acquired in the permanent memory (Fig. 7-6).
Selecting the limit (threshold) value for suppression
Q1
of minor unbalance readings in grams, or ounces.
S1
(Fig. 7-5) Select; (4), (B), (S), (S1),
Grams:
Range 3.5 to 20 g
Factory-adjusted value is 3.5 g
Threshold value display, e.g.: 3.5 g
Select another limit.
Type on the value set.
Ounces:
Range 0.12 to 0.71 oz
Factory-adjusted value is 0.12 oz
Threshold value display, e.g.: 0.12 oz
Select another value, e.g.: 0.2 oz
Type on the value set.
After the confi rmation, this operating mode can
be acquired in the permanent memory (Fig. 7-6).
* = Factory confi guration

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis