Herunterladen Inhalt Inhalt Diese Seite drucken

Sun SWB 340 Betriebsanleitung Seite 116

Inhaltsverzeichnis

Werbung

116
Downloaded from
www.Manualslib.com
manuals search engine
Troubleshooting
Gauge arm inputs differ from wheel dimensions
stated on rim or tyre.
1. Did you position the arm correctly?
• Refer to Chapter 5.4.
2. Check the offset input of the arm by entering the
value manually.
• Refer to the scale on the gauge.
• If not identical, proceed with step 4.
3. Check the diameter on the spot on the rim where
the diameter has been measured.
• If not identical, proceed with step 4.
4. Calibration is required.
• Have the gauge calibrated.
Balancing results are unreliable.
1. The balancer may not be installed properly.
• Make sure the unit rests on its three feet only.
• Make sure the fl oor is not transmitting shocks, for
example from trucks passing close to the unit.
2. The wheel may be mounted incorrectly.
• Check stub shaft, cones and adapters for clearance.
• Use appropriate spacers to eliminate play.
• Perform measuring unit calibration.
3. The electronic system may be faulty.
• Call technical service team.
A mode or indicator is continuously shown on the
screen.
1. A power dip may have occurred.
• Switch off the unit.
• Wait for 20 seconds, switch on the unit.
• Call technical service team.

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis