Herunterladen Inhalt Inhalt Diese Seite drucken

Description Of Controls; Using The Battery Pack - Pulsar Helion Bedienungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 28
5

DESCRIPTION OF CONTROLS

BUTTON
DEVICE STATUS
FIRST SHORT
(CURRENT
PRESS
OPERATING MODE)
ON
Device is off
Power device on Calibrate the sensor
Display OFF
Turn display on Calibrate the sensor
mode
Device is on
Calibrate the sensor
UP
Regular
Switch between colour palettes
(viewing)
Main menu
Hot menu
MENU
Enter hot menu n/a
Regular
(viewing)
M
Main menu
Hot menu
Switch between hot menu options
Regular
Control discrete digital zoom
DOWN
(viewing)
Main menu
Hot menu
REC
Video mode
Start video
recording
Photo mode
5
OTHER SHORT
LONG PRESS
PRESSES
Turn display off/
Power device off
Wi-Fi on/off
Navigation upwards/rightwards
Changes parameters
Enter main menu
Confirm selection
Exit submenu without
confirming selection /
Exit menu (switch to
viewing mode)
PiP on/off
Navigation downwards/leftwards
Changes parameters
Pause / resume video
Stop video recording
recording
(if recording is on)/
Switch to photo mode
(if recording is off)
Take a photograph
Switch to video mode
6

USING THE BATTERY PACK

HELION thermal imaging scopes are supplied with a rechargeable
Li-Ion Battery Pack IPS5 which allows operation for up to 8 hours.
Please remember to charge the Battery Pack before first use.
Charging:
Lift the lever (C) of the charger.
Remove the protective cover from the Battery Pack.
Install the Battery Pack into the charger by inserting the pins (A) of
the battery into the grooves (B) of the charger – the Pulsar logo on
the battery Pack should be located closer to the lever; click the lever
(C)(Pic.3).
Upon installation, a green LED indicator (D) on the charger will start
to glow and begin flashing:
- once if the battery charge ranges from 0% to 50%;
- twice if the battery charge ranges from 51% to 75%;
- three times if the battery charge ranges from 75% to 100%;
If the indicator glows green continuously, the battery is fully charged.
You can remove the battery from the charger by lifting the lever (C).
If the charger is not connected to the mains, the indicator glows
green for 15 sec.
If the indicator glows red continuously, the battery is defective. Do
not use the battery!
Connect the Micro-USB plug of the USB cable to the port (E) of the
charger.
Connect the Micro-USB plug to the charger.
Insert the plug of the charger to the 220V socket.
Pic.3
C
D
E
B
6

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis