Highest measured temperature
TMP
Test temperature, max. temperature (from the PC) before an
TMPT
attention is generated
Actual measured conductivity (RF RR LR LF)
A RF -
A LF
Enter a new illness:
ILT-
First field (2 digits) ; new illness code
Second field; not used
First field; actual illness code (from the PC)
ILC-
Second field; not used
Calendar items
Number of days in lactation
LACT
Number of days since the last heat. Present date is entered by filling
HEAT
in a 1. Filling in a 0 will restore the old value.
Number of days since the last insemination. Present date is entered
INSEM
by filling in a 1. Filling in a 0 will restore the old value.
Cow pregnant. Fill in 1=Yes, fill in 0=No.
INCALF
Number of days dry. Present date is entered by filling in a 1. Filling
DRY
in a 0 will restore the old value.

6.2 Warning; warning lamp, LED s and display

The MPC-2 features a red warning lamp, LED s and display, to notify the milker
of one or more exceptional situations.
There are three phases in which warnings can be generated;
From cow identification till end of neutral time
During milking
After removal of the cluster, until next cow is identified
Depending on these three situations the combination of LED and red warnings
lamp will have different meanings.
The table on the next page gives an overview of the different situations and the
meaning of the warning.
Press the relevant animal information function key corresponding to the
flashing/burning LED, when a warning occurs. The display will now alternate
with the item to which the warning applies.
Caution: Always press the information function key again to check if there are
more warnings.