After the cluster has been removed the milk data will be transferred to the
process controller. The next cows can now enter the milking parlour. If the milk
data has been transferred, the next identified cow will appear on the display.
The cluster can be attached to start the next milking session.
During milking it is always possible to end the milking session by pressing the
release cluster key.
If no cow is identified, the display and the red warning lamp start flashing. A
cow number can be entered manually (see chapter 3.4).
Caution: In case of milk separation, dry cow or colostrum, the red warning
lamp will be on. To start milking now, hold function-key automatic removal or
manual removal for at least three seconds, to lower the cluster.

3.2 Continue milking after kicking off the cluster

In case the cluster is already removed and the milking has to be continued,
e.g. after kicking off the cluster, the new milk yield can be added to the already
existing values:
Press the Shift-key.
Within 2 seconds press the function key automatic removal or manual
removal .
Reconnect the cluster and continue milking.
The milk data will now be added to the existing data, to finish with the correct
total milk yields.

3.3 Switching between manual and automatic removal

During milking it is always possible to switch between manual removal and
automatic removal, and vice versa. To do so:
Press function key automatic removal or manual removal .
The display shows what mode is currently in use by showing an h (manual),
or three horizontal dashes (automatic), on the sixth position.